Action List - 6060 Jonathans Bay Circle, Ste 301, Fort Myers
Inspected on Tuesday, January 25, 2022
You are now drafting Action List version 4
Courtesy of PSG Inspections LLC,
This tool lets you build your list quickly from the recommendations in the report.
  1. Select items for the list in the order you want them to appear.
  2. Edit text - add, remove or edit anything.
  3. Select an Action and $ amount (optional).
  4. Preview any time. Publish to PDF when finished
Your published PDF version(s) of this list
PDF Version 1 (Mar 2, 2022 07:45 AM)   Open  or  Download  or 
PDF Version 2 (Mar 2, 2022 08:05 AM)   Open  or  Download  or 
PDF Version 3 (Feb 24, 2024 12:02 PM)   Open  or  Download  or 
FROM THE REPORT SUMMARY
Item A) What the report said
Exterior • Roof drainage
Condition: Downspouts • Discharge too close to building
Location: Front Exterior
Task: Repair
Inspector notes: Discharge too close to building. The concrete gutter drain pan seems not to be level plus a brick is blocking the discharge not allowing it to drain onto the driveway. Recommend leveling concrete pan the and removing a brick.
What you want to say (edit below)
Action
Cost $
Item 1
FROM THE REPORT SUMMARY
Item B) What the report said
Electrical • Service box, grounding and panel
Condition: Service box
Location: Laundry Area
Task: Replace
Inspector notes: The electrical box front is missing two screws should replace. Square D
What you want to say (edit below)
Action
Cost $
Item 2
FROM THE REPORT SUMMARY
Item C) What the report said
Electrical • Distribution system
Condition: Outlets (receptacles) • Damage
Location: Front First Floor Porch
Task: Replace
Inspector notes: A GFCI next to the front door inoperative when test it need to be replace by a license electrician
What you want to say (edit below)
Action
Cost $
Select
FROM THE REPORT SUMMARY
Item D) What the report said
Electrical • Distribution system
Condition: Cover plates • Missing
Location: Rear Exterior
Task: Repair or replace
Inspector notes: Electric outlet cover is missing.
What you want to say (edit below)
Action
Cost $
Select
FROM THE REPORT SUMMARY
Item E) What the report said
Heating • Furnace
Condition: Filter • Dirty
Task: Replace
Inspector notes: Air filter dirty need to be changed out. The date on the filter showed March of last year
What you want to say (edit below)
Action
Cost $
Select
FROM THE REPORT SUMMARY
Item F) What the report said
Plumbing • Fixtures and faucets
Condition: Shower stall enclosure • Grout loose, missing or deteriorated
Location: Master Bathroom
Task: Repair or replace
Inspector notes: Grout missing have a license tile contractor repair
What you want to say (edit below)
Action
Cost $
Select
FROM THE REPORT SUMMARY
Item G) What the report said
Interior • Exhaust fans
Condition: Kitchen range exhaust system (range hood) • Blower inoperative
Location: Kitchen
Task: Repair or replace
Inspector notes: At time of inspection the microwave exhaust fan seen to be inoperative
What you want to say (edit below)
Action
Cost $
Select
When satisfied with your Previews, click here to   
(After publishing, you can make changes and click PUBLISH again to create Version 2, 3 etc. of the PDF)